FRCR MCQ--- Fetal dose from radiological examination
342.Correctly matched approximate dose to fetus from radiological
examination
a.chest PA ---- < 0.01 mGy
b.abdomen or pelvis AP ---1 mGy
c.lumber spine (AP and lateral0---1.5 mGy
d.barium follow through ----2 mGy
e.barium enema ---8 mGy
343. Correctly matched approximate dose to fetus from radiological
examination
a.CT chest --- 0.1 mGy
b.CT pelvis ---25 mGy
c.Tc-99m bone scan--- 4 mGy
d. Tc-99m thyroid scan --- 0.5 mGy
e. Tc-99m lung perfusion scan ---
0.3 mGy
OIN THIS SITE TO GET GET REGULAR POST (CLICK IN THE END OF PAGE--- JOIN THE SITE
OR FEED YOUR EMAIL )
ANSWER IN THE NEXT BLOG
POST YOUR ANSWER BELOW IN THE COMMENT
FRCR MCQ---Deterministic effect (non-stochastic effect)
334.True regarding deterministic effect (non-stochastic effect)
a.no effect above threshold dose
b.the rate at which the dose is delivered influences the threshold dose
c.most deterministic effect have no repair mechanisms
d.greatest fetal abnormality in the third week to third month week of pregnancy
e.large variation in threshold dose from individual to individual
334.ab
---Deterministic effect has threshold dose ,but there is small variation in
threshold from individual to individual.Most deterministic effect have repair
mechanisms ,except damage to eye.The greatest fetal abnormality is seen in the
third week to eigth week of pregnancy.(
Chapter 2,page no.25-26,second edition (2008),Farr’s Physics for Medical
Imaging).